NIBE F2025

Air/water heat pump with a new efficient scroll compressor that operates at temperatures down to -20 °C.

NIBE F2025 is an air/water heat pump, specially designed for the Nordic climate.

Image: Air source heat pumps/Product range/NIBE F2025

NIBE F2025 utilises the outside air so there is no need for bore holes or coils in the ground. NIBE F2025 is designed to be docked to water based heating systems. New efficient scroll compressor that operates at temperatures down to -20 °C. Automatic 2-step capacity regulator for the fan (not 6kW). Integrated intelligent control for optimum control of the heat pump.

NIBE F2025 is started by a start signal from another unit, return sensor or thermostat. The material has a long service life and is designed to withstand the Nordic outdoor conditions. NIBE F2025 can also be used together with most electric boilers, oil boilers or similar.

NIBE F2025 can be controlled from a specially designed control unit, SMO 10. This connects and disconnects additional heat and controls the changeover from room heating to domestic hot water heating.

Using accessory KVT 10, the condensation water that is created can be collected and routed to a suitable drain.

Image: Air source heat pumps/Product range/NIBE F2025
  2025-14
Delivered/Supplied power* at 2/35 °C ** 12,7/3,5 kW
Delivered/Supplied power* at 7/35 °C ** 14,5/3,7 kW
Delivered/Supplied power* at -7/45 °C ** 9,6/3,8 kW
Delivered/Supplied power* at 0/45 °C ** 11,7/4,0 kW
Delivered/Supplied power* at 7/45 °C ** 14,1/4,3 kW
Delivered/Supplied power* at -7/50 °C ** 9,5/4,2 kW
Delivered/Supplied power* at 2/50 °C ** 12,2/4,5 kW
Delivered/Supplied power* at 7/50 °C ** 13,9/4,6 kW
Delivered/Supplied power* at 15/50 °C ** 16,6/4,8 kW
Starting current 30 A
Motor protection setting 11 A
Soft-start relay included as standard
Operating voltage 3 x 400 V + N + PE 50 Hz
Compressor Scroll compressor
Nominal flow heating medium 0,34 l/s
Internal pressure drop at nominal flow 2,4 kPa
Air flow 2250/3050 m³/h
Nominal output fan 160/180 W
Fuse 16 A
Enclosure cla IP 24
Max outgoing heating medium temperature 58 °C
Refrigerant quantity (R404A) 2,4 kg
Connection heating medium male Ø G1 (Ø 28 mm)
Defrosting system hot gas defrosting
Height with stand 1045 mm
Width 1200 mm
Depth 520 mm
Weight 140 kg
Lowest operational point, outdoor air/flow line -20/50 °C (-7/58 °C)
Highest operational point, outdoor air/flow line 35/58 °C
* For compressor, ventilator and control. The relation between ”heating capacity and receptivity” must be reduced by approx. 10% during defrosting.
** Outside air temperature/flow temperature

 

Rights to make any design modifications are reserved..